TF930

CHF 398,00 Excl. 8.1% VATexcl. Shipping
In stock
SKU
1693634436.5834
Category
Counters
TF930 is available to buy in increments of 1

3GHz bench/portable universal counter with USB interface

Delivery time: approx. 3 weeks

AIM TTI - TF930

High measurement accuracy
The TF930 and TF960 use a high quality temperature compensated internal frequency reference (TCXO) which has a low aging rate and is stable to within ±1ppm over the full temperature range. Its short warm-up time allows accurate measurements to be made even under portable battery powered conditions. An External Reference input is provided and changeover from the internal timebase is automatic when an external reference standard is connected.
High resolution
For frequency, period and frequency ratio functions the instrument uses a reciprocal counting technique to provide high resolution at all frequencies. Eight significant digits of answer are produced in a 1 second measurement time, nine digits in 10s and ten digits in 100s with a granularity of less than 2 counts in the least significant digit.
Flexible signal conditioning
Input A has configurable coupling (AC or DC), input impedance (1MW or 50W), attenuation (1:1 or 5:1), threshold (fully variable) and active edge, and can be used for frequencies in the range 0.001Hz to >125MHz. Input B is a nominal 50W input for frequencies in the range 80MHz to
> 3GHz. Input C (TF960 only) uses a standard N connector and has a nominal 50W input for frequencies in the range 1.8GHz to > 6GHz.
Multiple measurement functions
The TF930 and TF960 can measure frequency, period, pulse width, duty cycle and frequency ratio, as well as event counting (totalise).
Remote control and read-back via USB
The TF930 and TF960 incporporate a USB interface which allows it to be remotely controlled using RS232 protocol via a computer’s USB port.
The remote commands of their predecessor instrument, the TF830, are compatible with the command set.
Battery operation when needed
The TF930 and TF960 operate from internal rechargeable NiMH batteries which give typically 24 hours operating life. The universal AC charger supplied will recharge the batteries in less than 4 hours and can be used for continuous AC operation. The instruments can also be powered from a standard USB port.
Ten digit LCD
The high contrast display has ten 12.5mm (0.5”) high digits along with a comprehensive set of annunciators. These show input configuration and function, measurement time and status, external reference connection, low battery and the units of the measurement which may be Hz, kHz, MHz, ns, us, ms or s.

Features:

  • 0.001Hz to > 3000MHz (TF930) or 6000MHz (TF960) frequency range
  • Frequency, period, pulse width, duty cycle, frequency ratio
    and event counting modes
  • High performance temperature compensated timebase
  • Reciprocal measurement technique gives superior resolution
  • High input sensitivity over the full frequency range
  • High impedance DC coupled input up to 125MHz
  • Variable trigger threshold and switchable attenuator
  • Large 10 digit LCD display with annunciators
  • Operation from built-in rechargeable batteries
  • Low power consumption gives up to 24 hours operation
  • Remote control and readback via USB interface


Customer Questions
No Questions
Please, mind that only logged in users can submit questions
TF930
Additional Information
CategoryCounters
Benchtop or HandheldBenchtop
Com. InterfaceUSB
# of NF Inputs2
Measurement Resolution [Digits] 10
Brandaim TTi
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
AIM-TF900_PFM3000_series_frequency_counters_data_sheet-Iss3A
Type: pdf
Size: 1.23 MB